capillary-thermostat.com
Capillary Thermostat,Liquid Inflated Temperature Controller,WK-R11
http://www.capillary-thermostat.com/capillary-thermostat.html
Langir Electric Co.,Ltd. 12288; Usage: It's mainly used for the temperature control of household electrical appliances (showers, rolling-type washers, fan heaters), electrothermal equipment (stainless steel full automatic water boilers, electrothermal fryers, baking stoves, electronic ovens, foodstuff machinery, medical equipment), and refrigeration industry (kitchen cooling cabinets, preservation cabinets, refrigerators, ice-makers, rearing ponds, cold-drinks makers, heating machines) etc. Do not press ...
capillary-thermostat.com
Snap-Action Thermostat,KSD301
http://www.capillary-thermostat.com/snap-action-thermostat.html
Langir Electric Co.,Ltd. Electrical Rating: 16A 125V AC(Resistive Load). 12288; 10A 250V AC(Resistive Load). 12288; 16A 250V AC(Resistive Load). Operating Temp: 50 175℃ (UL. CUL 205℃). Differential: 10 30K (15K Standard). Temp Tolerance: Operating Temp. ±3, ±5. Heat Durability: 220℃ Max. (PPS). Circuit Resistance: 50mΩ Max. Insulation Resistance: 100MΩ Min. at DC500V. Dielectric Strength: AC 1000V for 1m. 12288; AC 1800V for 1s. Operating Life: 100,000 Cycles (16A 125V/ 10A 250V AC).
capillary-thermostat.com
Check Method
http://www.capillary-thermostat.com/check-method.html
Langir Electric Co.,Ltd. Test on Rated Off Temperature. Test on Reset Temperature. Apply the method mentioned in article 1 to test reset temperature. Decrease the air temperature of the test chamber and lower the temperature when it is about 10K higher than the ceiling reset temperature at a cooling rate lower than 0.5K/min until the thermal protector resets. The temperature measured should accord with prescribed GB standard. Test on Service Life. Designed temperature: 0 90℃. Approval: TUV SEMKO CQC RoHS.
capillary-thermostat.com
Visualize
http://www.capillary-thermostat.com/visualize.html
Langir Electric Co.,Ltd. Applicable to be used as the function of temperature adjustment and control for the warm-air machine, water heater, milk-heater, electric cooker, electric iron, electric heater. Designed temperature: 0 90℃. Temp control range: 6 30℃ 6-35℃ 5-55℃ 0-70℃ 5-75℃. Voltage and current: AC250V 16A. This thermostat is rectangle,small size,regular act-temperature,the action rapid,reliable,unelectric-arc,and longevity. It can install at narrow position or set in some products.
capillary-thermostat.com
Langir Electric Co.,Ltd. professional for Thermostat,Capillary Thermostat,Liquid Expansion Thermostat,Bimetal Thermostat,Snap-Action Thermostat,KSD301
http://www.capillary-thermostat.com/index.html
Langir Electric Co.,Ltd. Langir Electric Co.,Ltd. is a professional manufacturing for Thermal Protector, Bimetal Thermostat, Capillary Thermostat, Snap-Action Thermostat(KSD301) and Kettle Thermostat and so on. With sincere services. the company is expecting to link your hands to create a better tomorrow. Applicable to be used as the function of temperature adjustment and control for the warm-air machine, water heater, milk-heater, electric cooker, electric iron, electric heater.
capillary-thermostat.com
World Clock
http://www.capillary-thermostat.com/world_time.html
Langir Electric Co.,Ltd. Move your mouse pointer over the world map and pop-up boxes will appear, detailing 'live' local times for a selection of worldwide locations. Applicable to be used as the function of temperature adjustment and control for the warm-air machine, water heater, milk-heater, electric cooker, electric iron, electric heater. Designed temperature: 0 90℃. Temp control range: 6 30℃ 6-35℃ 5-55℃ 0-70℃ 5-75℃. Voltage and current: AC250V 16A. Suitable for temperature control of electric kettle.
capillary-thermostat.com
Kettle Thermostat
http://www.capillary-thermostat.com/kettle-thermostat.html
Langir Electric Co.,Ltd. Name of Products: Kettle Coupler. Technical Parameter: 13A 250V 50Hz. Name of Products: Kettle Thermostat. Master Control Temp.: 80℃±5℃. Secondary Control Temp.: 120℃±5℃. Name of Products: Kettle Thermostat. Master Control Temp.: 80℃±5℃. Secondary Control Temp.: 120℃±5℃. Name of Products: Kettle Socket. Name of Products: Kettle Thermostat. Master Control Temp.: 120℃±5℃. Designed temperature: 0 90℃. Temp control range: 6 30℃ 6-35℃ 5-55℃ 0-70℃ 5-75℃. Voltage and current: AC250V 16A.
capillary-thermostat.com
Bimetal Thermostat, T90, AMT-90,AMT-P1 AMT-P2
http://www.capillary-thermostat.com/bimetal-thermostat.html
Langir Electric Co.,Ltd. KST401/ KST401P, T90. Applicable to be used as the function of temperature adjustment and control for the warm-air machine, water heater, milk-heater, electric cooker, electric iron, electric heater. Designed temperature: 0 90℃. Temperature control range: 6 30℃ 6-35℃ 5-55℃ 0-70℃ 5-75℃ etc. Temperature Control Precision: ±3℃. Life: 100,000 Cycles. Leakage Current: 0.5mA. Quickly respond to the variation of temperature, and has the function of automatic reset. Contact Closure Resis...
capillary-thermostat.com
Twinkling Thermostat,Fixed temperature controller,Adjustable temperature controller,Compensation temperature controller
http://www.capillary-thermostat.com/twinkling-thermostat.html
Langir Electric Co.,Ltd. Fixed temperature controller(KSD101). Adjustable temperature controller (KST201A/KST201B/KST201C). Rating scope AC125V 15A AC250V 10A. Maximum controlling temperature 265°C. Controlling precision ±5°C ±10°C. Reduction temperature 6-26°C. Maximum working temperature T300°C. Time of use 30,000 times. Pressure resistance grade 1500V AC/1min 2500V AC/1min. Insulating resistance 100mΩ 500VAC. Authorized specification CQC VDE UL. Designed temperature: 0 90℃. Approval: TUV SEMKO CQC RoHS.
SOCIAL ENGAGEMENT